2 2 4 R R
Operating instructions and warnings
21
9 MAINTENANCE
WARNINGAnyinstallation,maintenanceorrepairoperationonthewholesystemmustbecarried
outexclusivelybyqualifiedpersonnel.Alltheseoperationsmustbeperformedonlyafterdisconnecting
thepowersupply,andoperatinginstrictcompliancewiththeelectricalstandardsandregulationsin
forceinthenationofinstallation. A5
WARNING: With control boards range “RR” disconnect the power supply wires before
unlocking the operator manually. When you start the operator again the first operation
will bring the door to a complete closing. If you do not follow this procedure the door will
lose its right positioning.
10 PRODUCT DISPOSAL
InlinewithEUDirective2002/96/ECforwasteelectricalandelectronicequipment(WEEE),this
electricalproductmustnotbedisposedofasunsortedmunicipalwaste.Pleasedisposeofthisproduct
byreturningittoyourlocalmunicipalcollectionpointforrecycling.
11 COMPLETE CLOSING ASSEMBLY
Rememberthateveryonewhosellsand/ormotorisesdoors/gatesbecomesthemanufacturerofthe
automateddoor/gatemachine,andmustthereforeprepareandpreserveatechnicalfoldercontaining
thefollowingdocuments(seeMachineryDirectivesEnclosureV).
• Assemblydrawingoftheautomaticdoor/gate.
• Electricalconnectionandcontrolcircuitdiagram.
• Riskanalysisincluding:alistoftheessentialsafetyrequirementsprovidedinmachineDirective
EnclosureI;alistoftherisksposedbythedoor/gateandadescriptionoftheimplementedsolutions
Theinstallermustalso:
• Keeptheseoperatinginstructionsandtheinstructionsforallothercomponentsinasafeplace.
• Preparetheoperatinginstructionsandgeneralsafetywarnings(byfillinguptheseoperatinginstruc-
tions)andhandacopytotheenduser.
• Fillinthemaintenancehandbookandhandacopytotheenduser
• DrawuptheECdeclarationofconformityandhandacopytotheenduser.
• FillinthecompleteEClabelorplateandapplyittotheautomateddoor/gate.
N.B.Thetechnicalfoldermustbekeptforinspectionbythecompetentnationalauthoritiesforat
leasttenyearsstartingfromthedateoftheautomaticdoor/gatemanufacturing.
WARNINGDEASystemremindsallusersthattheselection,positioningandinstallationofallma-
terialsanddeviceswhichmakeupthecompleteautomationsystem,mustcomplywiththeEuropean
Directives2006/42/CE(MachineryDirective),2004/108/CE(electromagneticcompatibility),2006/95/
CE(lowvoltageelectricalequipment).Inordertoensureasuitablelevelofsafety,besidescomplying
withlocalregulations,itisadvisabletocomplyalsowiththeabovementionedDirectivesinallextra
Europeancountries.
WARNINGWrongassessmentofimpactforcesmaycauseseriousdamagetopeople,animaland
things.DEASystemremindsallpersonnelthattheinstallermustascertainthattheseimpactforces,
measuredaccordingtoEN12445prescriptions,areactuallybelowthelimitsindicatedbyEN12453
regulation.
WARNINGAnyexternalsafetydeviceinstalledinordertoconformtothelimitssetforimpactforces
mustcomplywithEN12978.