66
sliding gate Swing gate overhead door barriers
OPERATORS
CONFIGURATION
PARAMETERS
Selection type of operators • 000: GEKO
• 001: LOOK / MAC
• 002: GHOST
• 003: LIVI 500/502 / 902 / PASS
• 004: STOP
• 005: LIVI 5/24
• 006: LIVI 8/24
• 007: GULLIVER
Selected work with or without encoders.
CAUTION: Remember to correctly set the jumpers J5 and J9 (see table 1)
WARNING: J5, J9 and P029 must be set correctly before performing the procedure for programming
• 000: motors with encoder
• 001: engines without encoder
Selectioning operators number • 001: one operator
• 002: two operators
OPERATING PARAMETERS
Unused parameter
Operators speed adjustment during the stroke while opening 15%tot........................100%tot
Operators speed adjustment during the stroke while closing 15%tot........................100%tot
Operators speed adjustment during slow-down while opening and closing 15%tot........................100%tot
Slow down duration adjustment while opening 5%tot............................80%to
Slow down duration adjustment while closing 5%tot............................80%tot
Operator 1 force adjustment while opening
(if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
Operator n.1 force adjustment while closing
(if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
Operator n.2 force adjustment while opening
(if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
Operator n.2 force adjustment while closing
(if = 100% obstacle detection deactivated)
15%tot…...........................100%tot
Automatic closing times adjustment
(if = 0 automatic closing deactivated)
0sec...................................255sec
Pedestrian automatic closing time adjustment
(se = 0 pedestrian automatic closing deactivated)
0sec...................................255sec
Pedestrian stroke duration adjustment 5%tot…...........................100%tot
Pre-flashing time adjustment 0sec…….10sec
Adjustment of phase displacement time while opening 0sec……………30sec
Adjustment of phase displacement time while closing 0sec……………30sec
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of
automatic opening and closing
• 000: “collectivity function” deactivated
• 001: “collectivity function” activated
Ram blow function: it pushes the motors closed for one second before each opening movement, so as to ease
the electric-lock release
• 000: “ram blow” deactivated
• 001: “ram blow function” activated
“Reversal” mode selection (during the manoeuvre a command impulse reverse the mouvement) or “step by
step(during the manoeuvre a command impulse stops the mouvement). A next impulse restart the operator
to the opposite direction.
• 000: “reversal function”
• 001: “step by step function
PHOTO 1
PHOTO input functioning: if=0 photocells are enabled while closing and at start when gate is
closed; if=1 photocells are always enabled; if=2 photocells are enabled while closing only.
When enabled, its activation provokes: the inversion (while closing), the stop (while opening)
and prevent the starting (when gate is closed).
If=3-4-5, the operation is the same as the values 0-1-2 but with “close immediately” enabled:
in any case, during the opening and/or the pause time, removal of a possible obstacle causes
the gate automatically closes after a fixed delay of 3 sec.
• 000: photocells enabled while closing and at gate closed
• 001: photocells always enabled
• 002: photocells enabled only while closing
• 003: as 000 but with “close immediately” enabled
• 004: as 001 but with “close immediately” enabled
• 005: As 002 but with “close immediately” enabled
PHOTO 2
Operation mode selection of the warning light output:
If = 0 “warning light” (output always ON when the gate is open, OFF after a closing operation),
If = 1 “flashing warning light” (slow intermittent output during opening and fast while closing, always ON at
gate opened, always OFF at the end of a closing operation only),
If> 1 “courtesy light” (output ON during each movement, OFF when the motor stops, after the setting delay)
• 000: “fix warning light
• 001: “flashing warning light
• >001 : “courtesy light” off delay
(1sec………………255sec)