28
www.debem.it
Panneau
de danger
général
Placer les panneaux d’interdiction suivants à proximité du lieu d’installation de la pompe
Danger
matière
corrosive
Danger
matière
inammable
Danger
matière
explosive
Danger
matière
toxique
pericolo di
spruzzi di
materiale
liquido incan-
descente
divieto di
usare amme
libere
divieto di
fumare
ATTENTION: avant toute intervention sur la pompe
et/ou toute maintenance ou réparation, suivre la
marche cidessous:
A. vidanger le produit que vous êtes en train de pomper et
fermer les soupapes manuelles de captage du produit (aspi-
ration et refoulement);
B. Faire circuler un uidede lavage approprié qui ne soit pas
inamm-ble, ensuite le vidanger et fermer la soupape d’arrêt
du produit.
C. sectionner l’alimentation de l’air en intervenant sur la
soupape à 3 voies et s’assurer qu’il n’y a pas de pressions
résiduelles dans la pompe.
D. sectionner l’alimentation de l’air en haut;
E. Attendre le refroidissement de la pompe pendant au moins
quinze minutes;
F. Effectuer les opérations nécessaires en portant des gants
de protection individuels (masque facial, gants, chaussures
fermées, etc.): risque d’éjection de uidesous pression et de
brûlures).
!
MAINTENANCE DU CIRCUIT DU PROD.
C
A
÷ 0 bar
D
E
F
Put the following prohibition and danger signs near the place where the pump is installed
General
Danger Sign
Danger
Corrosive
Material
Danger
Flammable
Material
Danger
Explosive
Material
Danger Toxic
Material
Danger
Incandescent
Liquid Sprinkles
Prohibition
on Open
Flames’ Use
No smoking
WARNING: before intervening on the pump and/or
performing any maintenance or repair, you must:
A. discharge the product being pumped and close the product
on-off valves (both on the intake and delivery sides).
B. Circulate a suitable non-ammable washing uid then drain
it off and close the product shut-off valve.
C. Shut-off the air supply using the relevant three-way valve
whilst making sure that no residual pressure subsists.
D. Shut-off air supply upstream;
E. Wait for the pump to cool down for at least fteen minutes;
F. Perform the necessary operations while wearing protection
gloves and any other appropriate personal protection equipment
(face masks, gloves, closed shoes, etc.): DANGER OF BUR-
NING AND EJECTION OF LIQUID UNDER PRESSURE.