EasyManuals Logo

Dectron DRY-O-TRON Supervisaire DSV 020 User Manual

Default Icon
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #177 background imageLoading...
Page #177 background image
Dectron, Inc. March 2012
Owner’s Manual
DSH/DSV/RSH/DBH/RBH Series Dehumidifier
Check Blower Belts T.A.B.
Data subject to change without notice.
177
DECTRON
Belt
size
3.0 - 3.4
3.3
3.5
3.7
2.9
3.1
3.3
2.2
2.4
2.5
5.1
5.5
5.7
4.0
4.2
4.4
11.5
12.1
12.6
8.8
9.3
9.7
6.0
6.3
6.6
13.2
13.9
14.6
26.5
27.8
29.1
22.9
24.3
25.6
17.6
18.7
19.6
3.6 - 4.2
4.6 - 6.0
4.6 - 5.4
5.6 - 7.4
8.6 - 9.4
7.0 - 8.5
9.0 - 12.0
13.0 - 16.0
12.0 - 15.5
16.0 - 18.0
22.0 - 27.0
A
B
C
D
Small
sheave
diameter
(in)
Initial
Installation
Re-tensioning
Deflection force (lbs.)
Max. Min.
39.7
41.7
43.7
34.4
36.2
37.9
26.5
27.8
29.1
17.7 - 23.6
23.7 - 31.5
31.6 - 39.3
E
4.4
4.6
4.9
3.7
4.0
4.2
2.9
3.1
3.3
2.1 - 3.4
3.6 - 4.2
4.6 - 6.0
AX
7.7
8.2
8.6
6.6
7.1
7.5
5.1
5.5
5.7
3.7 - 5.4
5.6 - 7.4
8.6 - 9.4
BX
17.2
18.1
19.0
15.0
15.7
16.5
11.5
12.1
12.8
5.8 - 8.5
9.0 - 12.0
13.0 - 16.0
CX
5.5
6.4
7.5
4.8
5.7
6.6
3.9
4.4
5.1
2.65 - 3.35
19.2
23.3
27.3
16.7
20.3
23.8
13.0
15.6
18.5
7.1 - 8.5
9.0 - 11.8
12.5 - 16.0
5V
50.9
57.1
61.3
44.3
49.8
53.3
34.4
38.6
41.4
12.5 - 16.0
17.0 - 20.0
21.2 - 24.8
8V
19.2
23.3
27.3
16.7
20.3
23.8
13.0
15.6
18.5
4.4 - 8.5
9.0 - 11.8
12.5 - 16.0
5VX
3.65 - 4.12
4.5 - 5.6
8.6
7.5
5.7
6.0 - 10.6
3V
5.5
6.4
7.5
4.8
5.7
6.6
3.9
4.4
5.0
2.2 - 3.35
3.65 - 4.12
4.5 - 5.6
8.6
7.5
5.7
6.0 - 10.6
3VX
Where sheaves carry more than one belt, never replace only
one belt. If any belt must be replaced, replace all the belts with
new ones. When replacing multiple belts use only new belts
from the same manufacturer and the same lot number, or use
matched belts. Failure to do this will result in severe belt wear.
When removing or replacing belts, always
relieve the belt
tension to position the belts. Severe belt damage and
reduction of belt life can be caused by
1. prizing a belt onto a sheave, or
2. walking a belt onto a sheave.
Belt sheaves must be properly aligned, as shown below.
While the sheaves were aligned at the factory, future adjust-
ments may cause varying degrees of misalignment. A common
problem is parallel misalignment, as shown below. Parallel mis-
alignment causes excessive belt, sheave, and bearing wear.
Another common problem is angular misalignment, as shown
below. Angular misalignment causes excessive belt, sheave,
and bearing wear.
V-Belt Tensioning
Sheave
Sheave
Straight edge
Sheave
Sheave
Straight edge
Sheave
Sheave
Straight edge
Risk of contact with moving parts. Can cause injury or death.
This product contains rotating parts and V-belt drives. Some procedures could
expose personnel to the risk of injury or death from contact with these parts.
Using only approved devices (e.g. locking safety switch), disconnect, lockout, and
tagout all sources of electrical energy before working inside the unit cabinet. Allow
adequate time for rotating parts to stop. Follow all applicable safety regulations.
Do not operate the unit until ductwork or a screen is installed at each blower outlet.
WARNING
T.A.B.
5.9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dectron DRY-O-TRON Supervisaire DSV 020 and is the answer not in the manual?

Dectron DRY-O-TRON Supervisaire DSV 020 Specifications

General IconGeneral
BrandDectron
ModelDRY-O-TRON Supervisaire DSV 020
CategoryController
LanguageEnglish

Related product manuals