91
71.06952.02 - EN
INSTALLATION INSTRUCTIONS
The stainless steel plate-type water-water heat exchanger can be disassembled with a hex wrench by operating as de-
scribed below:
rESBJOUIFTZTUFNKVTUUIFCPJMFSJGQPTTJCMFthrough the drain tap;
rESBJOUIF%)8TZTUFN
rVOTDSFXUIFQJQFDPOOFDUJOHUIFFYQBOTJPOWFTTFMUPUIFIZESBVMJDBTTFNCMZ
rSFNPWFUIFIFBUJOHQSFTTVSFTXJUDI)XJUIPVUEJTDPOOFDUJOHUIFDBCMFIBSOFTT
rSFNPWFUIFUXPTDSFXTàH#BUUIFGSPOUTFDVSJOHUIFXBUFSXBUFSIFBUFYDIBOHFSBOEQVMMJUPVUVTJOHUIFTQBDF
created after removing the heating pressure switch;
rDMFBOUIFIFBUFYDIBOHFSBOEQVUJUCBDLJOQMBDF
rTDSFXPOUIFQJQFDPOOFDUJOHUIFFYQBOTJPOWFTTFMUPUIFIZESBVMJDBTTFNCMZ
rQVUUIFIZESBVMJDQSFTTVSFTXJUDICBDLJOQMBDF
32. DISMOUNTING THE WATER-WATER HEAT EXCHANGER
WARNING
Pay great attention when dismantling the individual parts of the hydraulic assembly.
Do not use sharp tools, do not apply excessive force when removing the xing clip.
Figure 16
CG_2078 / 1009_2201