EasyManua.ls Logo

Deger DEGERtracker D60H - Machines to be Provided by the Customer; Technical Data; Climatic Conditions According to DIN en 50178:1998-04

Deger DEGERtracker D60H
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24.03.2017 ASSEMBLY AND OPERATING MANUAL DEGERtracker D60H, D80, D100 Page 13
2.5.2 Machines to be provided by the customer
- Hoisting gear to unload transport vehicles (forklift truck, crane, etc.)
- Crane with 4-strand lifting tackle of at least 6 m length, load bearing capacity min. 1500 kg (0-45°), to lift the
rotating head with the mounted base frame
- Ladder, working platform to assemble rotating head, elevation drive and MLD-control. Strict compliance
with national regulations is mandatory
- GPS-receiver or compass
- Cordless drill and cordless screwdriver
2.6 Technical data
D60 H
D80
D100
Nominal output
(depending on module type)
4,000 … 7,000 Wp
6,000 … 10,000 Wp
8,000 … 12,000 Wp
Module surface up to
40 m²
53 m²
70.6 m²
Max. module surface up to (WxH)
8.3 m x 5.3 m
10.05 m x 5.6 m
11.95 m x 6 m
East - West rotation angle
300°
Angle of elevation (horizontal)
0° … 8
Control
DEGERenergie MLD
IP-protection class
IP 54/CAT 2 / UL50 Type 3R
Input voltage
100…240 VAC /50…60 Hz
Input rated current
0.3 A
Output voltage
24VDC
Max. continuous output current
2.5A
Power nominal Control mode
1 Watt
with running drive
24V / 0.4A / 10 Watt
24V / 0.6A / 15 Watt
24V / 0.7A / 18 Watt
Internal consumption per year
approx.
12 kWh
14 kWh
16 kWh
Drive AZ
Gear in drive head
Rotating speed AZ
30°/min
Drive EL
800 mm lift
Rotating speed EL
13°/min
Sound level
less than 70 dB(A)
Materials
Stainless steel, aluminum,
steel, plastic
Length of mast tube
3.40 m … 8.0 m
3.40 m … 8.0 m
4.0 m … 8.0 m
Weight (without mast/aluminum)
890 kg
930 kg
970 kg
Article No.
MLD-D60H
MLD-D80
MLD-D100
2.6.1 Climatic conditions according to DIN EN 50178:1998-04:
Installation above sea level max. 2,000 m
Permissible ambient temperature -20 °C to +50 °C
Extended humidity range 0 to 95 %
Extended air pressure range 70 kPa to 106 kPa
Snow load DEGERtracker D80 and D100 max. 10 kg/m²
Snow load DEGERtracker D60H max. 35 kg/m²
Dynamic wind pressure 0.5 to 1.35 kN/m² depending on terrain topography, mast
length, module configuration and wind zone.
2.6.2 Permitted tolerances
The horizontal SAFE position (table position) can have a tolerance of ±5°.

Table of Contents