RAID Level 0
CAUTION: RAID level 0 provides no redundancy. erefore, a failure
of one drive results in the loss of all data. Perform regular backups to
protect your data.
RAID level 0 uses data striping to provide a high data access rate. Data striping
writes consecutive segments, or stripes, of data sequentially across the physical
drive(s) to create a large virtual drive. is allows one of the drives to read data
while the other drive is searching for and reading the next block.
RAID 0 uses the full storage capacities of both drives. For example, two 2 GB hard
drives combine to provide 4 GB of hard drive space on which to store data.
NOTE: In a RAID 0 conguration, the size of the conguration is equal to
the size of the smallest drive multiplied by the number of drives in the
conguration.
RAID Level 1
RAID level 1 uses data mirroring to enhance data integrity. When data is written
to the primary drive, the data is also duplicated, or mirrored, on the secondary
drive in the conguration. RAID 1 sacrices high data-access rates for data
redundancy.
If a drive failure occurs, read and write operations are directed to the remaining
drive. A replacement drive can then be rebuilt using the data from the remaining
drive.
NOTE: In a RAID 1 conguration, the size of the conguration is equal to
the size of the smallest drive in the conguration.

Other manuals for Dell Alienware Aurora R3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Alienware Aurora R3 and is the answer not in the manual?

Dell Alienware Aurora R3 Specifications

General IconGeneral
BrandDell
ModelAlienware Aurora R3
CategoryDesktop
LanguageEnglish

Related product manuals