Features of BOSS-N1
Topics:
• Hot–plugging M.2 drives in BOSS-N1 Monolithic form factor
•
Identify M.2 drives by using LEDs
• Secure firmware update
• Foreign import of VDs
• Predictive failure analysis using the SMART feature
• Auto–rebuild a degraded drive
Hot–plugging M.2 drives in BOSS-N1 Monolithic form
factor
The unique controller design of the BOSS-N1 Monolithic carrier card allows you to hot plug M.2 drives. This feature reduces the
possibility of downtime during M.2 replacement.
NOTE:
The Integrated Dell Remote Access Controller (iDRAC) and Lifecycle Controller (LC) logs for the hot–plug events of
M.2 drives are generated.
Identify M.2 drives by using LEDs
BOSS-N1 Controller supports Activity and Status LEDs.
NOTE: Activity LED actions can be triggered by M.2 drive itself, it will blink Green during rebuild and I/O operations.
● Activity LED—The activity LED is triggered when an activity is initiated in M.2 drives.
● Status LED—The status LED is driven based on the drive status as mentioned in the following table:
Table 5. Status LED state
Status LED state Description
Green Drive is online
BLINK - Amber Drive is failed or has become SMART trip
BLINK - Green Drive is located or identified
NOTE: The locate or identify functionality is triggered using iDRAC and OpenManage
Server Administrator (OMSA).
OFF Drive is not present
Secure firmware update
Dell BOSS-N1 controller supports secure firmware update of BOSS-N1 controller firmware images. This means that each of the
firmware components is authenticated before being flashed. Authentication requires the use of a public/private asymmetric key
pair. If a firmware image is not authentic or any component with the image is not authentic, firmware image will not be flashed.
4
14 Features of BOSS-N1