EasyManua.ls Logo

Dell BOSS-N1 - Troubleshooting BOSS-N1 Issues; BOSS-N1 Single Drive RAID 0 Support Limitation; Unwanted 0.0 MB Unallocated Space Entry; BOSS-N1 HII Maximum VD Supported Display

Dell BOSS-N1
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
To get help with your Dell BOSS-N1, you can contact your Dell Technical Service representative or see https://www.dell.com/
support.
Topics:
BOSS-N1 supports only single drive RAID 0
Unwanted 0.0 MB unallocated space entry on BOSS-N1
BOSS-N1 HII displays Maximum VD supported as 2
RAID level (between RAID 0 and RAID 1) migration is not supported on BOSS-N1
BOSS-N1 supports only single drive RAID 0
Issue: BOSS-N1 allows physical connections of two M.2 NVMe drives. However, only one M.2 NVMe drive is
used to create RAID 0 volume and the other M.2 NVMe drive is not used.
Corrective
Action:
Expected behavior. No action is required.
Unwanted 0.0 MB unallocated space entry on BOSS-
N1
Issue:
If no RAID is created on drives connected to BOSS-N1 controller, one unwanted entry of 0.0 MB
unallocated space is displayed in the disk selection page during installation of the Windows operating
system.
Corrective
Action:
Expected behavior. No action is required.
BOSS-N1 HII displays Maximum VD supported as 2
Issue:
BOSS-N1 HII displays Maximum VD supported as 2. Considering one functional VD and one foreign VD,
HII displays Maximum VD supported as 2.
Corrective
Action:
Expected behavior. No action is required.
RAID level (between RAID 0 and RAID 1) migration is
not supported on BOSS-N1
Issue:
BOSS-N1 allows physical connections of two M.2 NVMe drives. Either you can create single drive RAID 0
or two drive RAID 1. After this RAID operation, RAID level migration is not supported.
Corrective
Action:
Expected behavior. No action is required.
9
32 Troubleshooting

Table of Contents

Related product manuals