S4112-ON Series
Setup Guide
Question and Answer IconNeed help?

Do you have a question about the Dell EMC S4112T-ON and is the answer not in the manual?

Summary

Site preparations

Switch ground

Emphasizes the importance of grounding the switch for safety and stability.

S4112-ON Series Installation

Ground cable

Detailed instructions for attaching a ground lug and cable to the switch chassis.

Rack or cabinet installation

Procedures for mounting the switch directly into a 19-inch rack or onto a shelf.

Half-RU front-rack installation

Guide for installing half-width switches using a dual tray in a four-post rack.

Switch installation

Steps to insert the switch into the dual tray mounted in the rack.

Switch removal

Instructions for safely releasing and removing the switch from the dual tray.

DC power connections

Explains how to connect DC power supplies to the switch using wiring blocks.

Specifications

Overview

The Dell EMC S4112-ON Series is a network switch designed for installation in network telecommunication facilities, data centers, and other locations where the National Electric Code (NEC) applies. This setup guide provides comprehensive instructions for site preparation, rack mounting, module insertion, and power connection. The series includes S4112F-ON and S4112T-ON models, both suitable for integration into a common bond network (CBN).

Function Description:

The S4112-ON Series switch serves as a networking device, facilitating data traffic within a network environment. It supports various configurations for power supply units (PSUs) and system fans, offering flexibility in airflow direction (normal or reverse). The switch is designed for reliable operation in demanding environments, with features for proper grounding and power management. It supports both AC and DC power sources, catering to different infrastructure requirements. The device also accommodates optical transceivers for high-speed data transmission.

Important Technical Specifications:

  • Chassis Physical Design:

    • Height: 1.75 inches (41.25 mm)
    • Width: 8.2 inches (209 mm)
    • Depth: 17.7 inches (450 mm)
    • Weight (with factory-installed components):
      • S4112F-ON: 8.30 lbs (3.76 kg) with 2 PSUs and 3 fans
      • S4112T-ON: 8.45 lbs (3.81 kg) with 2 PSUs and 3 fans
    • Rack Clearance Required: Front: 5 inches (12.7 cm), Back: 5 inches (12.7 cm)
  • Environmental Parameters:

    • Operating Temperature:
      • Continuous: 5°C to 40°C (50°F to 104°F)
      • Short term: -5°C to 45°C (23°F to 113°F) (Short term is <= 1% of operational hours per year)
      • Note: Reduce maximum temperature by 1°C/125 meters (1°F/228 feet) above 950 meters (3,117 feet).
    • Operating Humidity:
      • Continuous: 5% to 85% (RH), non-condensing
      • Short term: 5% to 90% (RH), non-condensing (Short term is <= 1% of operational hours per year)
    • Storage Temperature: -40°C to 65°C (-40°F to 149°F)
    • Storage Humidity: 5% to 95%, non-condensing
    • Maximum Thermal Output:
      • S4112F-ON: 180W, 614 BTU/hr
      • S4112T-ON: 200W, 682 BTU/hr
    • Maximum Operational Altitude: 10,000 feet (3,048 meters)
    • Maximum Non-operational Altitude: 39,370 feet (12,000 meters)
    • Shock: Dell EMC Spec SV0115
  • AC Power Requirements:

    • Power Supply: 100-240 VAC 50/60 Hz
    • Maximum Current Draw per System: 2A/1.7A at 100/120V AC, 1A/0.8A at 200/240V AC
    • Maximum Power Consumption:
      • S4112F-ON: 180 W
      • S4112T-ON: 200 W
    • Typical Power Consumption:
      • S4112F-ON: 90 W
      • S4112T-ON: 120 W
  • DC Power Requirements:

    • Minimum and Maximum Input Voltage Range: -40V, -72V DC, 5A Max
    • Maximum Input Current: -40V/5A, -48V/4.2A, -72V/2.8A
    • Start up VDC: 39.0 ± 1.5 V
    • Start off VDC: 37.5 ±1.5 V
    • DC Power Source Rating: -40 to -72 VDC, 6A minimum, Tma=40C, altitude operation of 3048m.
    • DC Power Cable: 10AWG, 16A minimum, with a 72V minimum rating.

Usage Features:

  • Installation Flexibility: The switch can be installed in network telecommunication facilities, data centers, and other locations adhering to the National Electric Code (NEC). It supports installation in indoor cabinets designed for controlled environments.
  • Rack Mounting: The S4112-ON Series can be mounted directly into a 19" wide, EIA-310-E-compliant rack or placed on a rack shelf. It supports half-RU front-rack installation using a dual-tray mounting system.
  • Airflow Management: The switch offers configurations for normal or reverse airflow, with fan speeds varying based on internal temperature monitoring. A minimum of 5 inches (12.7 cm) clearance around exhaust vents is required for proper ventilation.
  • Power Options: Supports both AC and DC power sources. AC power cables are included, while other power cables must be ordered separately. DC power connections involve a wiring block for secure wire insertion.
  • Optical Transceivers: The equipment contains optical transceivers, which comply with Class 1 laser radiation limits. Specific instructions are provided for installing and removing optics, emphasizing eye protection and careful handling.
  • Software Control: Module power is software controlled, meaning module LEDs may not be visible when the switch powers up in ONIE (Open Network Install Environment).
  • Documentation and Support: Dell EMC provides extensive documentation, software upgrades, patches, and management software through its support site (www.dell.com/support). ONIE documentation is available at www.onie.org, and third-party software users should consult their respective documentation.

Maintenance Features:

  • ESD Protection: Users are advised to wear ESD-preventive wrist or heel ground straps when handling the switch and its components to prevent electrostatic discharge damage.
  • Grounding: Dell EMC recommends grounding the switch with a dedicated ground wire, even for AC-powered switches where the power cord provides a ground path. For DC-powered switches, a dedicated ground wire is essential for safety. Grounding conductors must be made of copper.
  • Power Disconnection: Before servicing power supply slots, all power cords must be disconnected. For AC switches, the power supply cable serves as the main disconnect device and should be easily accessible.
  • Component Storage: If not immediately installed, components should be stored in a constant temperature range of -40°C to 65°C (-40°F to 149°F), on a dry, anti-static surface, away from direct sunlight, heat, air conditioning ducts, and dust.
  • Rack Safety: Rack loading should be balanced, and racks should be stabilized. Components should be mounted from bottom to top, ensuring the rack's load rating is not exceeded. Power sources and extension cords must not be overloaded.
  • Environmental Monitoring: The operating environment's ambient temperature and airflow must be maintained within specified limits to ensure safe and proper operation.
  • Battery Replacement: The device contains a lithium battery. Replacement should only be done with the same or equivalent type, and disposal must follow manufacturer's instructions to avoid explosion hazards.
  • Optical Fiber Safety: When working with optical fibers, eye protection is mandatory, and users should never look directly into terminated or unterminated fiber or connector ends due to potential laser radiation exposure.
  • Troubleshooting: The support site offers resources for technical support, including product-specific information accessible via a 7-character service tag or 11-digit express service code.

Dell EMC S4112T-ON Specifications

General IconGeneral
ModelS4112T-ON
CategorySwitch
Management Port1 x 10/100/1000BASE-T
Console Port1 x RJ-45
Input Voltage100-240V AC
Humidity10% to 90% non-condensing
ManagementWeb GUI, CLI, SNMP
Operating Temperature0°C to 40°C (32°F to 104°F)
Form Factor1RU
Power SupplyDual redundant power supplies
Weight8.6 kg (19.0 lb)