Linux system requirements
To deploy on Linux nodes in the VxFlex Ready Node environment, the following prerequisites must be met:
Note: For operating system installation guidelines, refer to the operating system vendor's documentation, taking
into account the VxFlex Ready Node prerequisites listed in this section.
l
Configure the M.2 device on the BOSS as a RAID 1 device.
l
During operating system installation, use Scaleio123 as the password for the user name root or administrator.
(Alternately, provide a password that meets the local security criteria.)
l
In a 2-Layer installation, Dell EMC supplies a VxFlex Ready Node image ISO.
Follow the wizard installation steps. The default password is Scaleio123. If required, you can change the
password by using the passwd command.
l
Install the operating system on the BOSS device.
Rebuild the RAID 1 boot device using the replaced M.2 module
The BOSS device consists of two 120/240 GB M.2 expansion cards. If necessary, rebuild the M.2 cards as a RAID 1
device.
Procedure
1. Power on the node.
2. In the iDRAC Virtual KVM console, press F2 immediately after you see the message F2 = System Setup
during system start up.
3. On the System Setup Main Menu screen, select Device Settings > AHCI Controller in Slot 2: BOSS-S1
Configuration Utility.
4. On the BOSS-S1 Configuration Utility screen, select Physical/Virtual Disk Information to verify the disk
configuration.
5. On the BOSS-S1 Configuration Utility > Operation Menu screen, select Physical Disk Info as the Device
Output Type, and then press Enter.
The physical disk information should display two expansion card devices configured to the server.
6. Select Virtual Disk Info as the Device Output Type, and then press Enter.
The configuration should show one virtual disk in a degraded RAID state configured on the server.
7. Click Back.
8. On the BOSS-S1 Configuration Utility screen, select Rebuild Raid.
You can monitor the status of the rebuild in the Storage > Virtual Disks screen. During the rebuild, the status of
the M.2 will be displayed as Degraded.
When the M.2 array is rebuilt, its status will be similar to the following:
VD_R1_1    Online
9. On the Virtual Disk Information screen, verify that the settings are configured as follows:
l
RAID Level: RAID1
l
Stripe Size: 64 K
l
Virtual Disk Size: 111/222 GB (The size will correspond to the M.2 device in use.)
l
Name: OS
Installing the Linux operating system