Table 10 R640 server configuration for 10/25GbE, 1CPU, SFP+/SFP28 (continued)
Description BMC
(iDRAC)
Monitoring
VxFlex OS
Data1
VxFlex OS
Client
Network
Port1
VxFlex OS
Client
Network
Port2
VxFlex
OS
Data2
VxFlex OS
Managemen
t Network
Not in Use
VMkernel port vmk2 User
configurable
User
configurable
vmk3 vmk0 N/A
Physical
Switch
Mgmt Switch Switch 1 Switch 1 Switch 2 Switch 2 Mgmt Switch/
Switch 2
N/A
Table 11 R640 server configuration for 10/25GbE, 2CPU, SFP+/SFP28
Description BMC
(iDRAC)
Monitoring
VxFlex OS
Data1
VxFlex OS
Client
Network
Port1
VxFlex OS
Client
Network
Port2
VxFlex
OS
Data2
VxFlex OS
Managemen
t Network
Not in Use
Port BMC (iDRAC) vmnic0 vmnic1 vmnic4 vmnic5 vmnic2 N/A
PCI slot N/A N/A N/A N/A N/A N/A N/A
Physical Port
on node
BMC (iDRAC)
(remote KVM)
PCI 10/25
GbE (Left)
PCI 10/25
GbE (Right)
PCI 10/25
GbE (Right)
PCI
10/25
GbE
(Left)
Onboard 1 GbE
(Left)
N/A
Speed 1 GbE 10/25 GbE 10/25 GbE 10/25 GbE 10/25
GbE
1 GbE N/A
vSwitch N/A sio_vSwitch1 User allocated User allocated sio_vSwi
tch2
vSwitch0 N/A
VMkernel port vmk2 User
configurable
User
configurable
vmk3 vmk0 N/A
Physical
Switch
Mgmt Switch Switch 1 Switch 1 Switch 2 Switch 2 Mgmt Switch N/A
This configuration supports more than one PCIe-based NIC in slots 2 and 3.
Configure the Management IP address - ESXi
Configure the Management IP address using the ESXi console.
Procedure
1. Open the ESXi KVM console.
2. From the console, press F2 to open the Customize System/View Logs menu.
The Authentication Required window is displayed.
3. Type the server password defined during installation: ScaleIO123
Wait a few seconds for the System Customization window to appear; if it does
not, press F2 again.
Port Configuration
Configure the Management IP address - ESXi 47