Upgrade Procedure Dell™ Networking 
N2024/N2024P/N2048/N2048P/N3024/N3024F/N3024P/N3048/N3048P 
Switches  
 
    Page 14     
Switch Recovery Example 
1.  Connect a serial cable to the serial console port of the switch (8-No Parity-1-9600-No Flow Control) 
 
2.  Power cycle the switch 
 
3.  When the boot menu appears, select 2 – Start Boot Menu 
 
Dell Networking Boot Options 
============================ 
Select a menu option within 3 seconds or the Operational Code will start automatically... 
 
1 - Start Operational Code 
2 - Display Boot Menu 
 
Select (1, 2) #
2 
 
Boot Main Menu 
============== 
 1 - Start Operational Code 
 2 - Select Baud Rate 
 3 - Retrieve Logs 
 4 - Load New Operational Code 
 5 - Display Operational Code Details 
 9 - Reboot 
 10 - Restore Configuration to Factory Defaults 
 11 - Activate Backup Image 
 12 - Start Password Recovery
 
4. 
If not already loaded, download the firmware to the switch using TFTP (Select option 4 - Load new 
operational code)  
 
Boot Main Menu 
============== 
1 - Start Operational Code 
2 - Select Baud Rate 
3 - Retrieve Logs 
4 - Load New Operational Code 
5 - Display Operational Code Details 
9 - Reboot 
10 - Restore Configuration to Factory Defaults 
11 - Activate Backup Image 
12 - Start Password Recovery 
Enter Choice# 4 
Creating tmpfs filesystem on /mnt/download for download...done. 
Current Active Image# /dev/mtd7 
Which Image to Update Active (/dev/mtd7) OR Back-Up (/dev/mtd6)? Select (A/B): A 
You selected to update Active Image /dev/mtd7... 
Select Mode of Transfer (Press T/X/Y/Z for TFTP/XMODEM/YMODEM/ZMODEM) []:T 
 
Please ensure TFTP server is running to begin Transfer... 
Enter Server IP []:10.10.10.200 
Enter Host IP []:10.10.10.224 
Enter Host Subnet Mask [255.255.255.0]:255.255.0.0