Using the Baseboard Management Controller 29
Table 1-27. Dell OEM Commands (NETFUN: 2EH, 2FH)
Commands NetFn CMD Request and Response
OemSetUbootEthaddr OEM 21H This command is for Dedicated-NIC. After
issuing the OEM command, user must reset
BMC manually.
REQUEST:
Byte 1–17: MAC address
Byte 18: End data — must be 00H
RESPONSE:
Byte 1 — Completion code
OemSetUbootEth1addr OEM 23H This command is for Shared–NIC. After
issuing the OEM command, user must reset
BMC manually.
REQUEST:
Byte 1–17: MAC address
Byte 18: End data — must be 00H
RESPONSE:
Byte 1 - Completion code