Using the Baseboard Management Controller 47
BIOS Version Information
The BIOS enables the system interface to the BMC and logs this event to the BMC early in POST.
BIOS version information is located in the event record, bytes 15 and16.
Example:
SEL list command:
ipmitool sel get 9
This indicates that the BIOS version is V1.1.
Table 1-39. POST Start Event
Byte Item Data
1–2 Record ID
3 Record Type
4–7 Timestamp
8–9 Generator ID 0x01 (BIOS)
10 Event Message Format Version 0x04 (IPMI 1.5)
11 Sensor Type 0xC1 (OEM reserved)
12 Sensor Number 0x81 (BIOS start)
13 Event Direction/Event Type 0x70 (OEM)
14 Event Data 1 0xA0
15 Event Data 2 0x01 (BIOS major version)
16 Event Data 3 0x01 (BIOS minor version)