Using the Baseboard Management Controller 35
14h PS 12V Voltage (02h) Threshold (01h) SI: 7Bh
SC: E8h
AM: 7A95h
DM: 7A95h
TM: 3F3Fh
15h PS 5V
16h STBY 3.3V
51h VCORE 1 Voltage (02h) Threshold (01h) SI: 7Fh
SC: E0h
AM: 0000h
DM: 0000h
TM: 3838h
52h VCORE 2
01h FCB FAN1 Fan (04h) Threshold (01h) SI:FCh
SC: E8h
AM: 2004h
DM: 0000h
TM: 3A3Ah
02h FCB FAN2
03h FCB FAN3
04h FCB FAN4
41h CPU1Status Processor (07h) Sensor-specific (6Fh) SI:63h
SC:C0h
AM:0012h
DM:0000h
TM:0012h
42h CPU2Status
40h SEL Fullness Event Logging Disable (10h) Sensor-specific (6Fh) SI: 63h
SC: 40h
AM: 0034h
DM: 0000h
RM: 0034h
60h Memory Memory (0Ch) Sensor-specific (6Fh) SI: 63h
SC: 40h
AM: 0023h
DM: 0000h
RM: 0023h
Table 1-32. Sensor Summary
Sensor
Number
Sensor Name Sensor Type Event/Reading Type Offset