28 About Your System
E1420 CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
E1421 CPU #
initialization
error. Power
cycle AC.
The system BIOS reported
a processor initialization
error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
E1422 CPU # machine
check error.
Power
cycle AC.
The system BIOS has
reported a machine
check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
E1610 Power Supply #
(### W)
missing.
Check power
supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supplies" on
page 155.
E1614 Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supplies" on
page 155.
E1618 Predictive
failure on
Power Supply #
(### W).
Check PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supplies" on
page 155.
Table 1-2. LCD Status Messages (Optional)
(continued)
Code Text Causes Corrective Actions
R415HOM.book Page 28 Friday, September 24, 2010 9:37 AM