96 Installing System Components
Figure 3-10. Removing and Installing a Redundant Power Supply
Installing a Redundant Power Supply
1
Verify that both power supplies are of the same type and have the same
maximum output power.
NOTE: The maximum output power (shown in watts) is listed on the power
supply label.
2
If applicable, remove the power supply blank. See "Removing the Power
Supply Blank" on page 97.
3
Slide the new power supply into the chassis until the power supply is fully
seated and the release latch snaps into place. See Figure 3-10.
NOTE: If you unlatched the cable management arm in step 1 of the previous
procedure, relatch it. For information about the cable management arm, see
the system’s rack documentation.
4
Connect the power cable to the power supply and plug the cable into a
power outlet.
CAUTION: When connecting the power cable, secure the cable with the
Velcro strap.
1 power supply 2 locking tab
3 cable retention bracket
1
2
3