Loading...
About Your System 39
W1628 Performance
degraded.
Check PSU and
system
configuration.
The system configuration
requires more power than
what the power supply can
provide, but it can boot if
throttled.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
W1630 Power supply
redundancy
degraded.
Check PSU
cables.
The power supply
subsystem is no longer
fully redundant.
Reseat the power
supplies. See
"Troubleshooting Power
Supplies" on page 155.
If the problem persists,
see "Getting Help" on
page 181.
NOTE: For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
Table 1-2. LCD Status Messages (Optional)
(continued)
Code Text Causes Corrective Actions