30 About Your System
E1710 I/O channel
check error.
Review & clear
SEL.
The system BIOS has
reported an I/O channel
check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 181.
E1711 PCI parity
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 165.
PCI parity
error on Slot
#. Review &
clear SEL.
The system BIOS has
reported a PCI parity
error on a component
that resides in the
specified slot.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 165.
Table 1-2. LCD Status Messages (Optional)
(continued)
Code Text Causes Corrective Actions