34 About Your System
E1A15 SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 181.
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 181.
E2010 Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
"Installing Memory
Modules" on page 124 or
"Troubleshooting System
Memory" on page 157.
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 157.
E2012 Memory
configured but
unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory" on
page 157.
E2013 BIOS unable to
shadow memory.
Check DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 157.
E2014 CMOS RAM
failure. Power
cycle AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 181.
Table 1-2. LCD Status Messages (Optional)
(continued)
Code Text Causes Corrective Actions