52 About Your System
Warning: Front
Control Panel is
not installed.
The control panel is not
installed or has a faulty cable
connection.
Install the control panel, or
check the cable connections
between the control panel
board and the system board.
See "Troubleshooting
System Memory" on
page 157.
Write fault.
Write fault on
selected drive.
Faulty USB device, USB
medium, optical drive
assembly, hard-drive, or hard-
drive subsystem.
Replace the USB medium or
device. Ensure that the USB,
SAS backplane, or SATA
cables are properly
connected. See
"Troubleshooting a USB
Device" on page 150,
"Troubleshooting an
Internal USB Key" on
page 159, and
"Troubleshooting a Hard
Drive" on page 163.
Incorrect memory
configuration
CPU n.
The DIMM group for CPU n
is incorrectly configured and
caused the system to halt.
See "General Memory
Module Installation
Guidelines" on page 122, for
memory configuration
information. If the problem
persists, see
"Troubleshooting System
Memory" on page 157.
HyperTransport
error caused a
system reset!
Please check the
system event log
for details!
A fatal system error occurred
and caused the system to
reboot.
Check the SEL for
information that is logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 149,
for any faulty components
specified in the SEL.
Table 1-3. System Messages
(continued)
Message Causes Corrective Actions
R415HOM.book Page 52 Friday, September 24, 2010 9:37 AM