Dell
PowerEdge T310 Technical Guide 31
5.4 Other Environmental Requirements
5.4.1 Maximum Vibration
Operating: 0.26 G at 5500 Hz for 15 min
Storage: 1.54 G at 10250 Hz for 15 min
5.4.2 Maximum Shock
Operating: One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6
ms in the operational orientation.
Storage: Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one
pulse on each side of the system) of 71 G for up to 2 ms.
5.4.3 Airborne Contaminant Level
Class: G2 or lower as defined by ISA-S71.04-1985
5.5 Maximum Input Amps
Under typical line conditions and over the entire system ambient operating range, the inrush current
may reach 25A (redundant power supply) and 35A (non-redundant power supply) per power supply for
10 ms or less.
5.6 Energy Star Compliance
See the Energy Star Compliance results on Dell.com.