EasyManua.ls Logo

Dell PowerFlex R750 - Component Installation Guidelines; Cable Routing Procedures

Dell PowerFlex R750
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Component installation guidelines
This section describes additional guidelines required for installing the drive backplane, expansion card risers, memory modules,
and other system components.
For detailed component installation instructions, see the Dell Technologies PowerFlex Custom Node R750 Field Replaceable Unit
Guide.
Cable routing
Figure 19. 8 x 2.5-inch SAS with NVMe and fPERC
Table 9. 8 x 2.5-inch SAS with NVMe and fPERC
From To
SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
SL1_CPU2_PB1 (signal connector on system board) BP_DST_PA1 (backplane signal connector)
SL2_CPU2_PA1 (signal connector on system board) BP_DST_PB1 (backplane signal connector)
SL3_CPU1_PB2 (signal connector on system board) and
SL4_CPU1_PA2 (signal connector on system board)
BP_DST_PA2 (backplane signal connector) and BP_DST_PB2
(backplane signal connector)
SL7_CPU1_PA5 (signal connector on system board) CTRL_DST_PA1 (fPERC input connector)
4
20 Component installation guidelines

Table of Contents

Related product manuals