DELL™ PRECISION™ T1650 TECHNICAL GUIDEBOOK
14
SYSTEM LEVEL ENVIRONMENTAL AND OPERATING CONDITIONS
Temperature
Operating 10° to 35° C (50° to 95° F)
Non-Operating (Storage) -40° to 60° C (-40° to 140° F)
Relative Humidity 20% to 80% (non-condensing)
Maximum vibration
Operating 0.25 G at 3 to 200 Hz at 0.5 octave/min
Non-Operating 0.5 G at 3 to 200 Hz at 1 octave/min
Maximum Shock
Operating
Bottom half-sine pulse with a change in velocity
of 50.8 cm/sec (20 inches/sec)
Non-Operating
27-G faired square wave with a velocity change
of 508 cm/sec (200 inches/sec)
Maximum Altitude
Operating –15.2 to 3048 m (–50 to 10,000 ft)
Non-Operating –15.2 to 10,668 m (–50 to 35,000 ft)
POWER
NOTE: These form factors utilize a more ecient Active Power Factor Correction (APFC) power supply. Dell recommends only Universal Power
Supplies (UPS) based on Sine Wave output for APFC PSUs, not an approximation of a Sine Wave, Square Wave, or quasi-Square Wave. If you
have questions, please contact the manufacture to conrm the output type.
Entry Upsell
Power Supply Wattage 275W 320W
AC input Voltage
Range
90 – 264Vac 90 – 264Vac
AC input current (low
ac range/high AC
range)
5.0A / 2.5A 5.0A / 2.5A
AC input Frequency 47Hz /63Hz 47Hz / 63Hz
AC holdup time (80%
load)
16 MSEC 16 MSEC
Average Eciency
(ENERGY STAR 5.2
qualied)
87 – 90 – 87% @ 20 – 50 – 100% load
Typical Eciency
(Active PFC)
65%