PROVISION FOR VENTILATION
The appliance should be installed into a room or space with an air supply in accordance
with the current version of BS 5440-2: 2000.
For rooms with a volume of less than 5m
3
- permanent ventilation of 100 cm
2
free area
must be provided.
For rooms with a volume of between 5 m
3
and 10 m
3
a permanent ventilation of 50 cm
2
free area will be required unless the room has a door which opens directly to the outside
air in which case no permanent ventilation is required.
For rooms with a volume greater than 10 m
3
- no permanent ventilation is required.
Note: Regardless of room size, all rooms containing the appliance must have direct
access to the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, the current version
of BS 5440-2: 2000 should be consulted to determine the correct amount of free area
ventilation requirements.
The above requirements allow also for use of a gas oven and grill but if there are other
gas burning appliances in the same room, consult a qualied engineer.