Chapter 7 Servo Parameters|ASDA-A&A+ Series
Revision April 2009 7-55
P2 - 12
DI3 Digital Input Terminal 3 (DI3) Communication Addr.: 020CH
Default: 116 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 13
DI4 Digital Input Terminal 4 (DI4) Communication Addr.: 020DH
Default: 117 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 14
DI5 Digital Input Terminal 5 (DI5) Communication Addr.: 020EH
Default: 102 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 15
DI6 Digital Input Terminal 6 (DI6) Communication Addr.: 020FH
Default: 22 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 16
DI7 Digital Input Terminal 7 (DI7) Communication Addr.: 0210H
Default: 23 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.