ASDA-A2  Chapter 8  Parameters 
Revision February, 2017    8-25 
 
Range: 
0 ~ 127 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
Please refer to Chapter 7.2.1, Description of Monitoring Variable for the 
setting value. 
 
P0-22 ~ 
P0-24 
 
Reserved 
 
P0-25    MAP1  Mapping Parameter # 1 
Address: 0032H 
0033H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section:  
4.3.5 
 
Default: 
No need to initialize 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
determined by the corresponding parameter 
of P0-35 
 
Data Size: 
32-bit 
 
Format: 
Hexadecimal 
 
Settings: 
Users can rapidly continuously read and write parameters that are not 
in the same group. The content of parameter that is specified by P0-35 
will be shown in P0-25. 
Please refer to the description of P0-35 for parameter setting. 
 
P0-26    MAP2  Mapping Parameter # 2 
Address: 0034H 
0035H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section:  
4.3.5 
 
Default: 
No need to initialize 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
determined by the corresponding parameter 
of P0-36 
 
Data Size: 
32-bit 
 
Format: 
Hexadecimal