ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-49
P1-08 PFLT
Smooth Constant of Position Command (Low-
pass Filter)
Address: 0110H
0111H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.6
Default
0
Control
Mode
PTPR
Unit
10 ms
Range
0 ~ 1000
Data Size
16-bit
Format
Decimal
Example
11 = 110 ms
Settings
0: Disabled
P1-09 SP1
Internal Speed Command 1Internal Speed
Limit 1
Address: 0112H
0113H
Operational
Interface
Panel / Software Communication
Related Section:
6.3.1
Default
1000
Control
Mode
ST
Unit
0.1rpm
Range
-60000 ~ +60000
Data Size
32-bit
Format
Decimal
Example
Internal speed command:
120 = 12 r/min
Internal Speed Limit: Positive value and
negative value is the same. Please refer to
the following description.