ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-183
P5-47 DLY7
Delay Time After Position Completed (Number
#7)
Address: 055EH
055FH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
1500
Control
Mode
PR
Unit
ms
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
The 8
th
Delay Time of PR mode
P5-48 DLY8
Delay Time After Position Completed (Number
#8)
Address: 0560H
0561H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
2000
Control
Mode
PR
Unit
ms
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
The 9
th
Delay Time of PR mode
P5-49 DLY9
Delay Time After Position Completed (Number
#9)
Address: 0562H
0563H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
2500
Control
Mode
PR
Unit
ms

Table of Contents