Chapter 8 Parameters ASDA-A2
8-190 Revision February, 2017
P5-60 POV0 Target Speed Setting #0
Address: 0578H
0579H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
20.0 200
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
15 = 15 r/min 150 = 15 r/min
Settings
The 1
st
target speed of PR mode
P5-61 POV1 Target Speed Setting #1
Address: 057AH
057BH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
50.0 500
Control
Mode
PR
Unit
1 r/min
0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 2
nd
target speed of PR mode