ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-195
P5-70 POV10 Target Speed Setting #10
Address: 058CH
058DH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
1500.0 15000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 11
th
target speed of PR mode
P5-71 POV11 Target Speed Setting #11
Address: 058EH
058FH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
1800.0 18000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 12
th
target speed of PR mode