ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-197
P5-74 POV14 Target Speed Setting #14
Address: 0594H
0595H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
2500.0 25000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 15
th
target speed of PR mode
P5-75 POV15 Target Speed Setting #15
Address: 0596H
0597H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
3000.0 30000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
32-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 16
th
target speed of PR mode