Chapter 8  Parameters  ASDA-A2 
8-216     Revision February, 2017 
engaged. It will automatically calculate the residual engaged length. E-Cam will 
disengage after rotating one cycle at forward direction. Users have to set P5-88.U 
to 2, 4, and 6; otherwise, the E-cam will not disengage. 
E-Cam will disengage when alarm occurs or the power supply is cut off. If users 
desire E-Cam to re-engage at the last disengaged position and continue its 
operation, it is recommended to record the disengaged position (X) and resume the 
operation by this macro command. Please note that when E-Cam is disengaged, 
the servo position might slightly shift and therefore cause position error when E-
Cam re-engages again. 
The Engaged direction is in forward direction (Master axis operates at forward 
direction): 
 
Note: When using this macro command, it would be better to execute this 
command before operate the master axis.
 
Failure code 
F0C1h 
When executing this macro command, E-Cam is not in 
engaged status. 
To modify the engaged position only when E-Cam is 
engaged. 
Failure code 
F0C2h 
The setting value of P5-93 is in error. The value cannot less 
than 0. It should > = 0. 
Failure code 
F0C3h 
The setting value of P5-93 is in error. The value has to less 
than the value of (P5-84 / P5-83) 
The following macros are available from version V1.038 sub48 (included): 
Command code 
000Dh 
Calculate the error between E-Cam and indexing coordinates 
for PR positioning. 
General 
Parameters 
N/A 
Macro Parameters  P5-93.Low_Word = DCBA: UZYX (8 digits, HEXADECIMAL) 
YX (PR number) = 0~0x3F (it is invalid when the value is set 
to 0) 
UZ: The value has to be set to 0. 
BA (Function of P5-95): 
0 (Use avoid point), 
 1 (Use available forward rate, V1.038 sub53)