Chapter 8  Parameters  ASDA-A2 
8-198     Revision February, 2017 
P5-76★ 
 
CPRS 
CAPTURE-First Position Reset Data 
Address: 0598H 
0599H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: 
7.10 
 
Default: 
0 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
-1073741824 ~ +1073741823 
 
Data Size: 
32-bit 
 
Format: 
Decimal 
 
Settings: 
Please refer to the description of P5-39 X 1 
 
 
P5-77■ 
 
CSAX 
The Position of Synchronous Capture Axis 
(CAP SYNC AXES) 
Address: 059AH 
059BH 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
0 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
-2147483648 ~ +2147483647 
 
Data Size: 
32-bit 
 
Format: 
Decimal 
 
Settings: 
The position of this axis will synchronize with CAP signal. That is to 
say, when activating CAP every two times, the motor moving distance 
of this axis is the value of P5-78. (There is no accumulative error and 
only in single-way operation) The synchronous capture axis can be the 
source of Master.