ASDA-M         Chapter 8 Parameters 
Revision December, 2014                                  8-47 
P1-06    SFLT 
Analog Speed Command (Low-pass 
Filter) 
Address: 010CH 
010DH 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: 
Section 6.3.3 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
0 
 
Control 
Mode: 
S 
 
Unit: 
ms 
 
Range: 
0 ~ 1000 (0: disable this function) 
 
Data Size: 
16bit 
 
Format: 
DEC 
 
Settings: 
0: Disabled 
 
P1-07    TFLT 
Analog Torque Command (Low-pass 
Filter) 
Address: 010EH 
010FH 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: 
Section 6.4.3 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
0 
 
Control 
Mode: 
T 
 
Unit: 
ms 
 
Range: 
0 ~ 1000 (0: disable this function) 
 
Data Size: 
16bit 
 
Format: 
DEC 
 
Settings: 
0: Disabled 
 
P1-08    PFLT 
Smooth Constant of Position 
Command (Low-pass Filter) 
Address: 0110H 
0111H 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: 
Section 6.2.6 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
0