Chapter 8 Parameters               ASDA-M 
8-48                Revision December, 2014 
 
Control 
Mode: 
PT/PR 
 
Unit: 
10 ms 
 
Range: 
0 ~ 1000 
 
Data Size: 
16bit 
 
Format: 
DEC 
 
Example: 
11 = 110 ms 
 
Settings: 
0: Disabled 
 
P1-09    SP1 
Internal Speed Command 1/Internal 
Speed Limit 1 
Address: 0112H 
0113H 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: 
Section 6.3.1 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
1000 
 
Control 
Mode: 
S/T 
 
Unit: 
0.1r/min 
 
Range: 
-60000 ~ +60000 
 
Data Size: 
32bit 
 
Format: 
DEC 
 
Example: 
Internal Speed Command: 120 = 12 r/min
Internal Speed Limit: Positive value and 
negative value is the same. Please refer 
to the following description. 
 
Settings: 
Internal Speed Command 1: The setting of the first internal speed 
command 
Internal Speed Limit 1: The setting of the first internal speed limit
 
 Example of inputting internal speed limit: 
 
Speed limit 
setting 
value of 
P1-09 
Allowable 
Speed 
Range 
Forward 
Speed Limit 
Reverse 
Speed Limit 
1000 
-100 ~ 100 
r/min 
100 r/min  -100 r/min 
-1000