ASDA-M         Chapter 8 Parameters 
Revision December, 2014                                  8-71 
 
P1-55    MSPD  Maximum Speed Limit 
Address: 016EH 
016FH 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: - 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
Same as the rated speed of each model 
 
Control 
Mode: 
ALL 
 
Unit: 
r/min 
 
Range: 
0 ~ max. speed 
 
Data Size: 
16bit 
 
Format: 
DEC 
 
Settings: 
The default of the max. speed of servo motor is set to the rated 
speed. 
 
P1-56    OVW  Output Overload Warning Level 
Address: 0170H 
0171H 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: - 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
120 
 
Control 
Mode: 
ALL 
 
Unit: 
% 
 
Range: 
0 ~ 120 
 
Data Size: 
16bit 
 
Format: 
DEC 
 
Settings: 
The setting value is 0 ~ 100, if the servo motor continuously 
outputs the load and is higher than the setting proportion (P1-56), 
the early warning for overload (DO is set to 10, OLW) will occur. 
If the setting value is over 100, it will disable this function. 
 
P1-57   Reserved 
Address: 0172H 
0173H 
 
P1-58   Reserved 
Address: 0174H 
0175H