DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
SMOV
M1168
D10
K2
D20
K3
K4
10
3
10
2
10
1
10
0
10
3
10
2
10
1
10
0
No variation No variation
D10(BIN 16bit)
D10(BCD 4 digits)
D20(BIN 16bit)
D20(BCD 4 digits)
Shift move
Auto conversion
Auto conversion
M1001
X0
If D10 = K1234, D20 = K5678 before execution, D10 remains unchanged and D20 = K5128
after execution.
Program example 2:
When M1168 = ON (in BIN mode) and SMOV instruction is in use, D10 and D20 will not be
converted in BCD format but be moved in BIN format (4 digits as a unit).
SMOV
M1168
D10
K2
D20
K3
K4
No variation No variation
D10(BIN 16bit)
D20(BIN 16bit)
Shift move
M1000
X0
Digit 4 Digit 3 Digit 2 Digit 1
Digit 4 Digit 3 Digit 2 Digit 1
If D10 = H1234, D20 = H5678 before execution, D10 remains unchanged and D20 = H5128 after
execution.