DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
3
-194
K12
Proportional value calculation function of multi-point areas (16-bit values)
Available for SEV1.0, ES2/EX2 V2.4, SA2/SX2 V2.0, SS2 V2.2
K13
Proportional value calculation function of multi-point areas (32-bit values)
Available for SEV1.0, ES2/EX2 V2.4, SA2/SX2 V2.0, SS2 V2.2
K14
Proportional value calculation function of multi-point areas (floating-point
values); Available for SEV1.0, ES2/EX2 V2.4, SA2/SX2 V2.0, SS2 V2.2
K15
Calculate the local time for sunrise and sunset
Available for ES2/EX2 V3.60, 12SA2/SX2 V3.00, ES2-E V1.4, SS2 V3.50,
12SE V1.92, 26SE V1.00, 28SA2 V2.90
K16
String combination function
Available for SA2 /SE V1.0, SX2 V1.2, ES2/EX2/SS2 V2.0
K17
String capture function
Available for SA2 /SE V1.0, SX2 V1.2, ES2/EX2/SS2 V2.0
K18
Convert data string to floating point value
Available for S SA2 /SE V1.0, SX2 V1.2, ES2/EX2/SS2 V2.0
K19
Convert floating point value to data string
Available for SA2 /SE V1.0, SX2 V1.2, ES2/EX2/SS2 V2.0
K30
Exchange the 16-bit data
Available for ES2/EX2 V3.42, ES2-C V3.48, 28SA2 V1.0, 12SA2/SX2 V3.00
K31
Copy word type data to the consecutive registers of the PLC
Available for ES2/EX2 V3.46, ES2-C V3.48, SA2/SX2 V2.86, SS2 V3.40
K32
Read the first written register to the D device (target value) and move the
second written register to the position of the first written register and so on.
(first in first out)
Available for ES2/EX2 V3.46, ES2-C V3.48, SA2/SX2 V2.86, SS2 V3.40
K33
Read the last written register (last in first out)
Available for ES2/EX2 V3.46, ES2-C V3.48, SA2/SX2 V2.86, SS2 V3.40
K34
Copy BIT type data to the consecutive registers of the PLC
Available for ES2/EX2 V3.46, ES2-C V3.48, SA2/SX2 V2.86, SS2 V3.40
K35
Read the first written BIT data and move the second written BIT data to the
position of the first written BIT data and so on. (first in first out)
Available for ES2/EX2 V3.46, ES2-C V3.48, SA2/SX2 V2.86, SS2 V3.40
K36
Read the last written BIT data (last in first out)
Available for ES2/EX2 V3.46, ES2-C V3.48, SA2/SX2 V2.86, SS2 V3.40
K39
Read PLC product serial number
Available for: ES2/EX2/ES2-C V3.48, 12SA2/SX2 V3.00, ES2-E V1.00, SS2
V3.48, 12SE V2.00, 26SE V1.00, 28SA2 V2.88

Table of Contents

Other manuals for Delta DVP-SS2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-SS2 and is the answer not in the manual?

Delta DVP-SS2 Specifications

General IconGeneral
BrandDelta
ModelDVP-SS2
CategoryController
LanguageEnglish

Related product manuals