3. Instruction Set
3-343
Received data (responding messages)
Data
Descriptions
‘0’
30 H
ADR 1
‘1’
31 H
ADR 0
‘0’
30 H
CMD 1
‘3’
33 H
CMD 0
‘0’
30 H
Number of data (count by byte)
A’
41 H
‘0’
30 H
Content of address
2100 H
PLC automatically converts
ASCII codes and store the
converted value in D1070 =
00C8 H
‘0’
30 H
‘C’
43 H
‘8’
38 H
‘7’
37 H
Content of address
2101 H
PLC automatically converts
ASCII codes and store the
converted value in D1071 =
7C08 H
‘C’
43 H
‘0’
30 H
‘8’
38 H
‘3’
33 H
Content of address
2102 H
PLC automatically converts
ASCII codes and store the
converted value in D1072 =
3E00 H
‘E’
45 H
‘0’
30 H
‘0’
30 H
‘9’
39 H
Content of address
2103H
PLC automatically converts
ASCII codes and store the
converted value in D1073 =
93AB H
‘3’
33 H
‘A
41 H
‘B’
42 H
‘0’
30 H
Content of address
2104 H
PLC automatically converts
ASCII codes and store the
converted value in D1074 =
0000 H
‘0’
30 H
‘0’
30 H
‘0’
30 H
‘2’
32 H
LRC CHK 1
‘A
41 H
LRC CHK 0