EasyManuals Logo

Delta DVP-SS2 User Manual

Delta DVP-SS2
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #967 background imageLoading...
Page #967 background image
DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
C-10
Special
D
Content
OFF

ON
STOP

RUN
RUN

STOP
Attrib.
Latch
-ed
Default
D1462*
Data length to be written on Slave ID#13
- - -
R/W
YES 16
D1463*
Data length to be written on Slave ID#14
- - -
R/W
YES 16
D1464*
Data length to be written on Slave ID#15
- - -
R/W
YES 16
D1465*
Data length to be written on Slave ID#16
- - - R/W
YES 16
D1480*
↓
D1495*
The data which is read from slave ID#1 in the PLC LINK at
the time when M1353 is OFF
0 - - R NO 0
The initial data register where the data read from slave
ID#1~ID#16 in the PLC LINK is stored at the time when
M1353 is ON
- - - R YES 0
D1496*
↓
D1511*
The data which is written into slave ID#1 in the PLC LINK at
the time when M1353 is OFF
0 - - R/W NO 0
The initial data register where the data written into slave
ID#1~ID#16 in the PLC LINK is stored at the time when
M1353 is ON
- - - R/W YES 0
D1512*
↓
D1527*
The data which is read from slave ID#2 in the PLC LINK
0 - - R NO 0
D1528*
↓
D1543*
The data which is written into slave ID#2 in the PLC LINK
0 - - R/W NO 0
D1544*
↓
D1559*
The data which is read from slave ID#3 in the PLC LINK
0 - - R NO 0
D1560*
↓
D1575*
The data which is written into slave ID#3 in the PLC LINK
0 - - R/W NO 0
D1576*
↓
D1591*
The data which is read from slave ID#4 in the PLC LINK
0 - - R NO 0
D1592*
↓
D1607*
The data which is written into slave ID#4 in the PLC LINK
0 - - R/W NO 0
D1608*
↓
D1623*
The data which is read from slave ID#5 in the PLC LINK
0 - - R NO 0
D1624*
↓
D1639*
The data which is written into slave ID#5 in the PLC LINK
0 - - R/W NO 0
D1640*
↓
D1655*
The data which is read from slave ID#6 in the PLC LINK
0 - - R NO 0
D1656*
↓
D1671*
The data which is written into slave ID#6 in the PLC LINK
0 - - R/W NO 0
D1672*
↓
D1687*
The data which is read from slave ID#7 in the PLC LINK
0 - - R NO 0
D1688*
↓
D1703*
The data which is written into slave ID#7 in the PLC LINK
0 - - R/W NO 0

Table of Contents

Other manuals for Delta DVP-SS2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-SS2 and is the answer not in the manual?

Delta DVP-SS2 Specifications

General IconGeneral
BrandDelta
ModelDVP-SS2
CategoryController
LanguageEnglish

Related product manuals