EasyManuals Logo

Delta DVP-SS2 User Manual

Delta DVP-SS2
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #975 background imageLoading...
Page #975 background image
DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
C-18
Special
M
Function
OFF

ON
STOP

RUN
RUN

STOP
Attrib.
Latch-
ed
Default
M1130
For COM2(RS-485), STX/ETX selection
OFF OFF - R/W NO OFF
M1131
For COM2(RS-485), ON when MODRD/RDST/MODRW
data is being converted from ASCII to Hex
OFF OFF - R NO OFF
M1132
ON when there are no communication related instructions in
the program
OFF - - R NO OFF
M1136*
For COM3(RS-485/USB), retaining communication setting
OFF - - R/W NO OFF
M1137
Retain DNET mapping data during non-executing period
- - - R/W NO OFF
M1138*
For COM1 (RS-232), retaining communication setting.
Modifying D1036 will be invalid when M1138 is set.
OFF - - R/W NO OFF
M1139*
For COM1(RS-232), ASCII/RTU mode selection (OFF:
ASCII; ON: RTU)
OFF - - R/W NO OFF
M1140
For COM2 (RS-485), MODRD / MODWR / MODRW data
receiving error
OFF OFF - R NO OFF
M1141
For COM2 (RS-485), MODRD / MODWR / MODRW
parameter error
OFF OFF - R NO OFF
M1142
Data receiving error of VFD-A handy instructions
OFF OFF - R NO OFF
M1143*
For COM2(RS-485), ASCII/RTU mode selection (OFF:
ASCII; ON: RTU)
OFF - - R/W NO OFF
M1161
8/16 bit mode (ON = 8 bit mode)
OFF - - R/W NO OFF
M1162
Switching between decimal integer and binary floating point
for SCLP instruction.
ON: binary floating point; OFF: decimal integer
OFF - - R/W NO OFF
M1167
16-bit mode for HKY input
OFF - - R/W NO OFF
M1168
Designating work mode of SMOV
OFF - - R/W NO OFF
M1177
Enable the communication instruction for Delta VFD series
inverter.
ON: VFD-A (Default), OFF: other models of VFD
OFF - - R/W NO OFF
M1200
C200 counting mode (ON: count down)
OFF - - R/W NO OFF
M1201
C201 counting mode (ON: count down)
OFF - - R/W NO OFF
M1202
C202 counting mode ON: count down)
OFF - - R/W NO OFF
M1203
C203 counting mode (ON: count down)
OFF - - R/W NO OFF
M1204
C204 counting mode (ON: count down)
OFF - - R/W NO OFF
M1205
C205 counting mode (ON :count down)
OFF - - R/W NO OFF
M1206
C206 counting mode (ON: count down)
OFF - - R/W NO OFF
M1207
C207 counting mode (ON: count down)
OFF - - R/W NO OFF
M1208
C208 counting mode (ON: count down)
OFF - - R/W NO OFF
M1209
C209 counting mode (ON: count down)
OFF - - R/W NO OFF
M1210
C210 counting mode (ON: count down)
OFF - - R/W NO OFF
M1211
C211 counting mode (ON: count down)
OFF - - R/W NO OFF

Table of Contents

Other manuals for Delta DVP-SS2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-SS2 and is the answer not in the manual?

Delta DVP-SS2 Specifications

General IconGeneral
BrandDelta
ModelDVP-SS2
CategoryController
LanguageEnglish

Related product manuals