EasyManua.ls Logo

Delta DVP02LC-SL

Delta DVP02LC-SL
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DVP02LC-SL
Load Cell Module
Operation Manual
DVP-0071020-01

Other manuals for Delta DVP02LC-SL

Question and Answer IconNeed help?

Do you have a question about the Delta DVP02LC-SL and is the answer not in the manual?

Delta DVP02LC-SL Specifications

General IconGeneral
ModelDVP02LC-SL
Input Voltage24 VDC
Analog Input Channels2
Number of Digital Inputs8
Number of Digital Outputs6
Communication PortsRS-232, RS-485
SeriesDVP
Product SeriesDVP
Input Impedance10 MΩ
Current Consumption100 mA
Output TypeRelay
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 70°C
Humidity5% to 95% RH (non-condensing)
Dimensions90 x 90 x 65 mm

Summary

Theory of Load Cell

Introduction to DVP02 LC-SL

Functions

Lists the technical specifications and capabilities of the load cell module.

Effective Number of Bits (ENOB)

Explains the ENOB based on load cell eigenvalue and reaction time.

Product Profile and Outline

Dimensions

Provides the physical dimensions of the DVP02LC-SL module.

Product Profiles

Identifies and labels the main components and ports of the module.

Terminal Layout

Details the pin assignments for CH1 and CH2 channel connections.

LED Indicators

Explains the function of each LED status indicator on the module.

Installation and Wiring

Connecting DVP02 LC-SL to PLC MPU

Describes the physical connection procedure between modules.

DIN Rail Installation

Outlines the steps for mounting modules onto a DIN rail.

Communication Wiring

Details the wiring and pin definitions for communication ports.

External Wiring

Illustrates how to wire load cells to the module's channels.

Functions of DVP02 LC-SL

Control Registers (CR)

Lists and describes the control registers (CR) and their addresses.

Control Register Explanations

Provides detailed explanations for specific control registers.

Function Explanations

Explains specific functions of the load cell module.

Measure the Weight

Standstill Check

Determining Zero Point

Filtering

Setting up DVP02 LC-SL in Software

Initial Settings

Guides through the initial connection and communication setup.

Communication Settings

Configures communication parameters for RS-232 and RS-485.

Parameter Settings

Sets up measurement parameters like units, times, and limits.

Correction Settings

Details the zero point and weight base point correction procedures.

Status Settings

Explains how to view measuring results and status/error codes.

Steps of Correction

Correction by MPU

Describes how to perform correction using the PLC MPU.

Correction by Software

Details the procedure for calibrating via the software interface.

Application Examples

Tension Control

Demonstrates using DVP02LC-SL in a tension control application.

LED Indicators and Trouble-shooting

LED Indicators

Explains the meaning of all LED indicators on the module.

Trouble-shooting

Lists common problems and their solutions for the module.