Chapter 9 SpecificationsMS300
181
230V models three-phase
Frame
A
B
C
Model VFD_ _ _ _ _ _ _ _AA
1A6MS23_ _ _
2A8MS23_ _ _
4A8MS23_ _ _
7A5MS23_ _ _
11AMS23_ _ _
ANS
ENS
ANS
ENS
ANS
ENS
ANS
ENS
ANS
ENS
Applicable Motor Output (kW)
0.2
0.4
0.75
1.5
2.2
Applicable Motor Output (HP)
1/4
1/2
1
2
3
Outpu
t*
Heavy Duty
Rated Output Capacity (kVA)
0.6
1.1
1.8
2.9
4.2
Rated Output Current (A)
1.6
2.8
4.8
7.5
11
Carrier Frequency (kHz)
2–15 (Default: 4)
Normal Duty
Rated Output Capacity (kVA)
0.7
1.2
1.9
3.0
4.8
Rated Output Current (A)
1.8
3.2
5
8
12.5
Carrier Frequency (kHz)
2–15 (Default: 4)
Input
Rated Input
Current (A)
Heavy Duty
1.9
3.4
5.8
9.0
13.2
Normal Duty
2.2
3.8
6.0
9.6
15
Rated Voltage / Frequency
Three-phase 200240 V
AC
(-1510%), 5060 Hz
Mains Input Voltage Range (V
AC
)
170–265
Mains Frequency Range (Hz)
4763
Weight (kg)
0.65
0.68
0.81
1.05
1.24
Cooling Method
Convective cooling
Fan cooling
EMC Filter
Optional
IP Rating
IP20
IP40*
IP20
IP40*
IP20
IP40*
IP20
IP40*
IP20
IP40*
Table 9-4
NOTE:
1. Output*: Default is heavy duty.
2. IP40*: The IP ratings of the wiring area (main circuit terminals and control terminals for frame A/B/C/D/E/F)
and the vent near the capacitor (frame C/D/E/F) are both IP20.
3. The value of the carrier frequency is a factory default. Decrease the current value if you need to increase the
carrier frequency. Refer to Section 9-7 Derating for Ambient Temperature and Altitude for details.
4. For shock or impact load applications, select a drive with a larger capacity model.

Table of Contents