Chapter 13 CANopen Overview |C200 Series
13-26
Display
Fault code Description
CANopen
fault code
CANopen
fault
register
(bit 0~7)
Thermal relay 2
Fault
ovU
Unknow Over volt.
Fault
0043H Over voltage caused by unknown reason 3210H 2
Thermal relay 2
Fault
S1
S1-Emergy stop
Fault
0049H External emergency stop 9000H 5
Thermal relay 2
Fault
OPHL
U phase lacked
Fault
0052H U phase output phase loss 3131H 2
Thermal relay 2
Fault
OPHL
U phase lacked
Fault
0053H
V phase output phase loss
3132H 2
Thermal relay 2
Fault
OPHL
U phase lacked
Fault
0054H
W phase output phase loss
3133H 2
Thermal relay 2
Fault
aocc
A
phase short
Fault
004FH A-phase short 2240H 1
Thermal relay 2
Fault
bocc
B phase short
Fault
0050H B-phase short 2240H 1
Thermal relay 2
Fault
cocc
C phase short
Fault
0051H C-phase short 2240H 1
Thermal relay 2
Fault
CGdE
Guarding T-out
Fault
0065H Guarding time-out 1 8130H 4
Thermal relay 2
Fault
CHbE
Heartbeat T-out
Fault
0066H Heartbeat time-out 8130H 4
Thermal relay 2
Fault
CSyE
SYNC T-out
Fault
0067H CAN synchrony error 8700H 4
Call 1(800)985-6929 for Sales