Chapter 11 Summary of Parameter SettingsCP2000 
 
11-22 
  Pr.  Parameter Name  Setting Range  Default 
  05-20 
Magnetizing inductance (Lm) for 
induction motor 2 
0.0–6553.5 mH  0.0 
  05-21 
Stator inductance (Lx) for 
induction motor 2 
0.0–6553.5 mH  0.0 
  05-22  Induction motor 1 / 2 selection 
1: Motor 1 
2: Motor 2
 
1 
  05-23 
Frequency for Y-connection / 
ᇞ-connection switch for an 
induction motor 
0.00–599.00 Hz  60.00 
  05-24 
Y-connection / 
ᇞ-connection 
switch for induction motor 
0: Disable 
1: Enable
 
0 
  05-25 
Delay time for Y-connection / 
ᇞ-connection switch for an 
induction motor 
0.000–60.000 sec.  0.200 
  05-28 
Accumulated Watt-hour for a 
motor (W-hour) 
Read only  0.0 
  05-29 
Accumulated Watt-hour for a 
motor in low word (kW-hour) 
Read only  0.0 
  05-30 
Accumulated Watt-hour for a 
motor in high word (MW-hour) 
Read only  0.0 
  05-31 
Accumulated motor operation 
time (Min.) 
0–1439  0 
  05-32 
Accumulated motor operation 
time (Day) 
0–65535  0 
  05-33 
Induction motor (IM) or 
permanent magnet motor (PM) 
selection 
0: IM (Induction motor) 
1: SPM (Surface permanent magnet synchronous 
motor) 
2: IPM (Interior permanent magnet synchronous motor) 
0 
  05-34 
Full-load current for a permanent 
magnet motor 
Depending on the model power 
Depending 
on the 
model 
power
 
  05-35 
Rated power for a permanent 
magnet motor 
0.00–655.35 kW 
Depending 
on the 
motor 
power 
  05-36 
Rated speed for a permanent 
magnet motor 
0–65535 rpm  2000 
  05-37 
Pole number for a permanent 
magnet motor 
0–65535  10 
  05-38 
System inertia for a permanent 
magnet motor   
0.0–6553.5 kg-cm
2
 
Depending 
on the 
motor 
power 
  05-39 
Stator resistance for a permanent 
magnet motor   
0.000–65.535   0.000 
  05-40  Permanent magnet motor Ld  0.00–655.35 mH  0.00 
  05-41  Permanent magnet motor Lq  0.00–655.35 mH  0.00 
  05-43 
Ke parameter for a permanent 
magnet motor 
0–65535 (Unit: V / krpm)  0