Chapter 3 Installation MS300 (High Speed Model) 
 
3-1
Chapter 3 Installation 
Minimum Mounting Clearance and Installation   
  Prevent fiber particles, scraps of paper, shredded wood saw dust, metal particles, etc. from adhering 
to the heat sink 
  Install the AC motor drive in a metal cabinet. When installing one drive below another one, use a 
metal separation between the AC motor drives to prevent mutual heating and to prevent the risk of 
accidental fire. 
  Install the AC motor drive in Pollution Degree 2 environments only: normally only nonconductive 
pollution occurs and temporary conductivity caused by condensation is expected.   
The appearances shown in the following figures are for reference only.   
Airflow direction: 
  inflow   outflow           distance 
Single drive installation 
 
Side-by-side horizontal installation 
 
Minimum mounting clearance 
Installation method  A (mm)  B (mm) C (mm) 
Ambient temperature (
o
C) 
Max. (Without derating)  Max. (Derating)
Single drive installation  50  30  -  50  60 
Side-by-side horizontal installation  50  30  30  50  60 
Zero stack installation  50  30  0  40  50 
 
NOTE
 
The minimum mounting clearances A~C stated in the table above applies to AC motor drives installation. Failing to 