Industrial Automation Headquarters
Delta Electronics, Inc.
Taoyuan Technology Center
18 Xinglong Road, Taoyuan District,
Taoyuan City 33068, Taiwan (R.O.C.)
TEL: 886-3-362-6301 / FAX: 886-3-371-6301
Asia
Delta Electronics (Jiangsu) Ltd.
Wujiang Plant 3
1688 Jiangxing East Road,
Wujiang Economic Development Zone
Wujiang City, Jiang Su Province, P.R.C. 215200
TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290
Delta Greentech (China) Co., Ltd.
238 Min-Xia Road, Pudong District,
ShangHai, P.R.C. 201209
TEL: 86-21-58635678 / FAX: 86-21-58630003
Delta Electronics (Japan), Inc.
Tokyo Ofce
2-1-14 Minato-ku Shibadaimon,
Tokyo 105-0012, Japan
TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211
Delta Electronics (Korea), Inc.
1511, Byucksan Digital Valley 6-cha, Gasan-dong,
Geumcheon-gu, Seoul, Korea, 153-704
TEL: 82-2-515-5303 / FAX: 82-2-515-5302
Delta Electronics Int’l (S) Pte Ltd.
4 Kaki Bukit Ave 1, #05-05, Singapore 417939
TEL: 65-6747-5155 / FAX: 65-6744-9228
Delta Electronics (India) Pvt. Ltd.
Plot No 43 Sector 35, HSIIDC
Gurgaon, PIN 122001, Haryana, India
TEL : 91-124-4874900 / FAX : 91-124-4874945
Americas
Delta Products Corporation (USA)
Raleigh Ofce
P.O. Box 12173,5101 Davis Drive,
Research Triangle Park, NC 27709, U.S.A.
TEL: 1-919-767-3800 / FAX: 1-919-767-8080
Delta Greentech (Brasil) S.A.
Sao Paulo Ofce
Rua Itapeva, 26 - 3° andar Edicio Itapeva One-Bela Vista
01332-000-São Paulo-SP-Brazil
TEL: 55 11 3568-3855 / FAX: 55 11 3568-3865
Europe
Delta Electronics (Netherlands) B.V.
Eindhoven Ofce
De Witbogt 20, 5652 AG Eindhoven, The Netherlands
TEL: +31 (0)40-8003800 / FAX: +31 (0)40-8003898
*We reserve the right to change the information in this user manual without prior notice.
Delta Standard Compact Drive
MS300 Series
User Manual
(High Speed Models)
Delta Standard Compact Drive - MS300 Series User Manual
(High Speed Models)
5014063800-E0MS-20170
3
www.eleris.ru
www.eleris.ru

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Delta VFD25AMS43ANSHA and is the answer not in the manual?

Delta VFD25AMS43ANSHA Specifications

General IconGeneral
ModelVFD25AMS43ANSHA
CategoryController
BrandDelta
Output Current25A
Power Rating11 kW
Frequency Range0.1 - 400 Hz
Cooling MethodFan Cooling
AltitudeUp to 1000m without derating
Enclosure RatingIP20
Communication InterfaceRS-485
Input Voltage3-phase 380-480V AC
Control MethodV/F control, Sensorless Vector Control
Communication ProtocolModbus
Protection FeaturesOverload, Overvoltage, Undervoltage, Overheating
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to 60°C
Humidity5% to 95% (non-condensing)

Summary

Chapter 3 Installation

Minimum Mounting Clearance and Installation

Guidelines for minimum mounting clearances and installation requirements.

Chapter 4 Wiring

4-1 Wiring

General wiring instructions for AC motor drives, including safety precautions.

4-2 System Wiring Diagram

Illustrates the system wiring diagram for AC motor drives, detailing component connections.

Chapter 5 Main Circuit Terminals

5-1 Main Circuit Diagram

Provides a schematic diagram of the main circuit connections for the AC motor drive.

Chapter 7 Optional Accessories

7-1 All Brake Resistors and Brake Units Used in AC Motor Drives

Details on selecting applicable brake resistors and brake units for improved drive performance.

Chapter 8 Option Cards

8-1 Option Card Installation

Step-by-step instructions for installing option cards into the AC motor drive.

8-2 CMM-MOD01 MODBUS TCP Option Card

Details features, profile, specifications, and communication parameters for the MODBUS TCP option card.

8-3 CMM-PD01 PROFIBUS Option Card

Provides features, profile, specifications, and connector pin assignments for the PROFIBUS option card.

8-4 CMM-DN01 DeviceNet Option Card

Details functions, profile, specifications, and LED indicators for the DeviceNet option card.

8-5 CMM-EIP01 MODBUS TCP/EtherNet IP Option Card

Covers features, profile, specifications, and communication parameters for the EtherNet/IP option card.

8-6 CMM-COP01 CANopen Option Card

Details product profile, RJ-45 pin definition, specifications, and CANopen communication cable.

Chapter 9 Specification

9-1 230V Series

Provides detailed specifications for 230V series AC motor drives, including 1-phase and 3-phase models.

9-2 460V Series

Provides detailed specifications for 460V series AC motor drives, including 3-phase models.

9-3 Environment for Operation, Storage and Transportation

Details environmental conditions for operation, storage, and transportation, including temperature and humidity.

9-4 Derating of Ambient Temperature and Altitude

Provides derating curves for ambient temperature and altitude affecting output current rating.

Chapter 10 Digital Keypad

Descriptions of Keypad Functions

Explains the functions and displays of various keypad buttons and items.

Keypad operation process

Details the step-by-step process for operating the keypad, including main page selection and parameter setting.

Chapter 11 Summary of Parameter Settings

14 Protection Parameters (2)

Details protection parameters for malfunctions like output frequency, DC voltage, and IGBT temperature.

Chapter 12 Description of Parameter Settings

00 Drive Parameters

Details drive parameters including identity codes, rated current, and parameter reset options.

01 Basic Parameters

Covers basic parameters like max operation frequency, output voltage, and mid-point settings for motors.

02 Digital Input / Output Parameters

Explains digital input/output parameters, including operation control modes and multi-function terminals.

03 Analog Input / Output Parameters

Details analog input/output parameters like selection, gain, bias, and filter times.

06 Protection Parameters (1)

Details protection parameters for low voltage, over-voltage stall prevention, and over-current stall prevention.

07 Special Parameters

Covers special parameters like software brake, DC brake, restart after fault, and dEb function.

09 Communication Parameters

Details communication parameters for RS-485, CANopen, and DeviceNet, including address and speed settings.

Chapter 13 Warning Codes

Modbus function code error (Illegal function code)

Corrective actions for Modbus function code errors, emphasizing function code correctness.

Modbus data address is error (Illegal data address (00 H to 254 H))

Corrective actions for Modbus data address errors, focusing on communication address correctness.

Modbus data error (Illegal data value)

Corrective actions for Modbus data errors, advising to check data value against max/min.

IGBT is over-heated than protection level 1~10 HP: 90 °C

Corrective actions for IGBT overheating, focusing on ambient temperature and ventilation.

Chapter 14 Error Codes

Over-current during acceleration (Output current exceeds triple rated current during acceleration.)

Corrective actions for over-current during acceleration, including checking motor output and drive power.

Over-current during deceleration (Output current exceeds triple rated current during deceleration.)

Corrective actions for over-current during deceleration, focusing on acceleration time and drive power.

Over-current during steady state operation (Output current exceeds triple rated current during constant speed.)

Corrective actions for over-current during steady state operation, checking motor output and drive power.

DC-BUS over-voltage at constant speed (230V: 450 VDC; 460 V: 900 VDC)

Corrective actions for DC-BUS over-voltage, including checking input voltage and regenerative voltage.

DC-BUS over-voltage during deceleration (230V: 450 VDC; 460V: 900 VDC)

Corrective actions for DC-BUS over-voltage during deceleration, suggesting increased deceleration time.

DC-BUS voltage is less than Pr. 06-00 during acceleration.

Corrective actions for low DC-BUS voltage during acceleration.

DC-BUS voltage is less than Pr. 06-00 during deceleration.

Corrective actions for low DC-BUS voltage during deceleration.

Phase Loss.

Corrective actions for phase loss in 3-phase or 1-phase applications.

IGBT is over-heated than protection level.

Corrective actions for IGBT overheating, focusing on ambient temperature and ventilation.

Overload. The AC motor drive detects excessive drive output current.

Corrective actions for overload, suggesting checking motor loading or higher power model.

Motor overheating.

Corrective actions for motor overheating, checking obstructions and ambient temperature.

Chapter 15 CANopen Overview

15-5 CANopen Fault Codes

Lists CANopen fault codes, their descriptions, and corresponding fault registers.

Chapter 16 PLC Function Applications

16-3 Turn on

Steps for connecting to PC and implementing PLC functions on the MS300.

16-7 Error display and handling

Provides guidance on handling and recommended approaches for various PLC error codes.

Chapter 17 Safe Torque Off Function

17-1 Basic Function Description

Provides a basic description of the MS300 Safe Torque Off (STO) function and its international specifications.

17-2 Safe Torque Off Terminal Function Description

Describes the terminal functions related to STO, including signal inputs and action logic.

17-3 Wiring Diagram

Illustrates wiring diagrams for the safe control loop, including internal circuits and external connections.

17-7 Error Code and Troubleshooting Instructions

Provides descriptions for STO relevant error codes and their corresponding corrective actions.

17-8 Test and Fault Confirmation

Step-by-step instructions to check the normal operation of STO and related detection functions.