Chapter 16 PLC Function ApplicationsC2000 Plus
16-56
API
SRET
Conclusion of subprogram
02
P
Bit device Word device
16-bit command (1 STEP)
FEND
Continuous
execution type
32-bit command
Flag signal: none
X Y M K H KnX KnY KnM T C D
Notes on operand usage:
No operand
A contact-driven command is not needed
A contact-driven command is not needed. Automatically returns next command
after CALL command
Indicates end of subprogram. After end of subprogram, SRET returns to main
program, and executes next command after the original call subprogram CALL
command.
Refer to the FEND command explanation and sample content for detailed
command functions.